Inductance extremum
Minimum and maximum values:
The minimum value of inductance (L) is determined by the requirements of the minimum load current to be maintained.
The current flowing through the inductor L is divided into two operating conditions: continuous and discontinuous. In either case, as long as the input and output voltages remain unchanged, the slope of the current waveform will not change due to the reduction of the load current.

If the load current I gradually decreases and the minimum fluctuation current in the inductor L is just zero, defined as the critical current Ioc, then Ioc should be equal to -half of the current peak and peak, that is, Ioc=1/2△iL
When Io<Ioc, iL enters the discontinuous state. When Io≥Ioc, iL is continuous.
The closed-loop control circuit of the single-end excited converter is shown in the figure. Cc in the figure is the distributed capacitance of the demagnetization reset winding △. The continuous transfer function has two poles; The transfer function of the discontinuous state has only one pole, and careful design is necessary if the transfer function is to work stably throughout the state transition.
Closed-loop control circuit of single-end excited converter
Another limiting factor for the L value will arise when applied to multiple sets of output voltages.
Because the control loop is closed to only one associated output, when the current at this output is below the critical value, the duty cycle is reduced to keep the voltage at this output constant. For the other auxiliary outputs, assuming that they are carrying a constant load, the voltage also decreases when the duty cycle decreases as described above. Obviously this is not desired, so in the case of multiple sets of output voltages, in order to keep the auxiliary output voltage constant, the value of the inductor L should be greater than the required minimum. That is to say, if the auxiliary voltage is to be maintained within a certain fluctuation range, the inductance of the main output must always exceed the critical value, that is, it is always in a continuous state.
The maximum value of inductors is generally limited by efficiency, volume and cost, and the cost of large inductors operating with DC current is expensive. From the point of view of J energy, the inductance L is too large will slow down the reaction speed of the regulating system. Because the large L limits the maximum rate of change of the output current when the load has a large transient change.
Contact: Miss Zhao
Mobile: 15001738747
Email: postmaster@maylandzc.com
Website: www.maylandzc.com
Address: No. 1185, Huyi Road, Jiading District, Shanghai